PST-2500MF Adaptor / Power Supply Test Report

 
Load Current / mA Voltage / V Noise / mV dB w/1000uF Regulation
3.29 0         *
3.30 3.18        
3.27 197.5     *   0.67%
3.11 2400        
3.06 2500   *   1.6%
 
4.46 55   *
4.45 190      
4.38 1000       *   1.8%
4.34 1500    
4.29 2003        
4.25 2500       *   2.9%
 
5.25 4.5 100 -34.4    
5.24 59    

5.23

195       *
5.16 1000    
5.08 2000    
5.03 2500       *   3.8%
 
6.31 1 150 -32.5
6.27 50         *
6.28 250    
6.27 420    
6.22 1030   *   0.8%
6.14 2001        
6.04 2500   *   2.9%
 
8.48 8 175 .33.7     *
8.46 200
8.44 440 200 -32.5     *   0.5%
8.44 460
8.43 570  
8.40 1030        
8.35 1500 400

-26.4

  *   1.0%
8.32 2000  
8.28 2500

450

-25.3

  *   0.8%
8.28 2500 450 -25.3 -34.8  
           

 Remarks:

  1. Input voltage varied from 100vac to 135vac, output did not change.

  2. Regulation measured from points indicated by *

  3. Some noise figures taken with 1000uF across output terminals.

  Conclusion:

  These adaptors demonstrate very good regulation over wide range of loads, with good noise figures. In some cases, the regulation  

  exceeds expectations.

  Tests done on:  Wavetek Model: DM78a DMM

                         Circuitmate 9020 20MHz 'scope Vertical amplifier shows nominal 4% error.

                         Phoenix Arizona, USA

                         July 18-20 2004

 

 If more information is needed on the testing party, please contact us.

 