PST-1800MF Adaptor/Power Supply Test Report

Voltage / V Load Current / mA Noise mV  P-P dB w/1000uF Regulation
3.11 120 200 -23.8
3.07 500 150 -26.0   *
3.03 1000 250
2.99 1500 300 110 -19.9 -28.7   *   2.6%
2.97 1760
2.96 1850 350 130 -18.5 -27.1   *   1%
 
4.64 22
4.61 32 140 -30.3   *
4.55 1000 230 -26.0   *   1.3%
4.51 1580 320 -23.0
4.49 1800 350 -22.1   *   1.3%
 
6.17 50 450 -22.7   *
6.16 200 150 -32.2

6.13

580 225 -28.7   *   0.65%
6.10 1000 550 -21.7
6.05 1600 375 -24.0
6.03 1880 390 -23.8   *   1.6%
 
7.62 54.4 200 -31.6
7.61 100 200 85 -31.6 39   *
7.60 230 220 -30.7
7.56 800 250+ -29.0
7.53 1170   *   1%
7.47 1860
 
9.13 200 135 50 -33.2 -45.2   *
9.10 500
9.06 1140 350 125 -28.2 -37.2
9.02 1600
9.00 1800   *   1.4%
 
12.37 210 150 50 -38.3 -47.8   *   1%
12.34 550 300
12.30 1000 400
12.20 1500
12.24 1830 500 200 -27.7 -35.7   *   1%

   Remarks:

    1. Input voltage varied from 100vac to 135vac, output measured 12.36V at 320mA. Output did not change.

    2. Regulation measured from points indicated by *. Example: 500mA-1500mA, 1500mA-1850mA

    3. Some noise figures taken with 1000uF across output terminals.

   Conclusion:

    These adaptors show good long-term stability with good regulation and relatively low noise.

   Tests done on:  Wavetek Model: DM78a DMM

                          Circuitmate 9020 20MHz 'scope

                          Phoenix Arizona, USA

                          July 18-19, 2004

 